MXGC100-40N-SM Replacement Filter Cartridge | Parker Fulflo MaxGuard Compatible

MemKway MXGC100-40N-SM replacement filter cartridge is designed as a compatible alternative for selected Parker Fulflo MaxGuard systems. It features 10 μm pleated cellulose media in a 40-inch configuration for industrial liquid filtration.

Unlike MXGP models that use polypropylene media, MXGC cartridges use cellulose media. Final compatibility should be confirmed by OEM part number, dimensions, seal configuration and process fluid.

1. Core Specifications

Parameter

Specification

Brand

MemKway

Model

MK-MXGC-100-40N

Market Equivalence

Equivalent to Parker MaxGuard series MXGC100-40N-SM

Micron Rating

10 μm (Absolute)

Flow Direction

Outside-to-Inside

Nominal Length

40 in (1016 mm)

Outer Diameter

6 in (152 mm)

Internal Diameter

2 in (51 mm)

End Cap Style

226 O-ring with integrated handle

2. Parker MXGC100-40N-SM Compatible Filter Cross Reference

Parker ModelMemKway ReplacementRatingMediaLength
MXGC100-40N-SMMK-MXGC-100-40N10 μmCellulose40 in
MXGP050-40N-SMMK-MXGP-050-40N5 μmPP40 in
MXGP100-40N-SMMK-MXGP-100-40N10 μmPP40 in
MXGP200-40N-SMMK-MXGP-200-40N20 μmPP40 in

3. Materials of Construction

The MXGC100-40N-SM replacement filter combines cellulose filter media with polypropylene support and structural components. Media suitability should be confirmed based on the process fluid, temperature and chemical compatibility requirements.

  • Filter Media: Cellulose
  • Support/Drainage: Polypropylene
  • Hardware (Cage/Core): High-strength Polypropylene
  • End Caps: Reinforced Polypropylene
  • O-ring Seal: Buna-N Standard (EPDM, Silicone and Viton available upon request)

4. MXGC vs MXGP – What Is the Difference?

FeatureMXGC SeriesMXGP Series
Filter MediaCellulosePolypropylene
Typical Selection BasisCompatible industrial liquidsWater and broader PP-compatible fluids
Chemical CompatibilityMore application-dependentGenerally broader than cellulose
Model ExampleMXGC100-40N-SMMXGP100-40N-SM

5. Recommended Operating Conditions

  • Maximum Operating Temperature: 176°F (80°C) @ 30 psid (2.1 bar)
  • Maximum Forward Differential Pressure: 70 psid (4.8 bar) @ 77°F (25°C); 30 psid (2.1 bar) @ 176°F (80°C)
  • Recommended Change-out differential pressure: 35 psid (2.4 bar)
  • Maximum Flow Rate: 90 GPM (340 LPM)

6. Pressure Drop vs. Flow Rate

Flow Rate (gpm)Flow Rate (lpm)Pressure Drop (psi)Pressure Drop (mbar)
20760.002 0.15 
401510.004 0.30 
602270.007 0.46 
803020.009 0.61 
903400.010 0.68

7. Typical Applications

The MXGC100-40N-SM replacement filter excels in high-flow environments:

  • Water Treatment: Desalination and RO membrane pre-filtration.
  • Oil & Gas: Produced water and amine loop filtration.
  • Chemical Processing: Selected process-water and compatible process-fluid applications.
  • Power Plants: Condensate polishing and cooling systems.

8. Key Features & Benefits

  • Compatible Installation: Designed for selected Parker MaxGuard MXGC100-40N-SM filtration systems.
  • 10 μm Cellulose Media: Intended for particulate removal in compatible industrial liquid applications.
  • 40-Inch Large-Format Design: Supports high-flow industrial filtration applications.
  • 226 Seal Configuration: Buna-N sealing with other elastomer options available for selected operating conditions.
  • Cross-Reference Support: Model selection can be confirmed using OEM part number, dimensions and seal configuration.

9. Quality & Regulatory Compliance

  • ISO 9001:2015: Manufactured in a certified facility with strict quality controls.
  • FDA Compliance: Materials meet FDA Title 21 CFR for food and beverage contact.
  • Batch Traceability: Every MXGC100-40N Replacement Filter is batch-coded for full transparency.

10. Disclaimer

All manufacturers’ names, product names, and part numbers (including Parker and MaxGuard) are used for reference purposes only. MemKway is an independent manufacturer and is not affiliated with the original equipment manufacturers.

Frequently Asked Questions (FAQ)

Q1: What is the filtration rating of MXGC100-40N-SM replacement filter?

A1: MemKway MXGC100-40N-SM replacement filter configuration uses 10 μm cellulose pleated media for particulate removal in industrial liquid filtration applications.

Q2: What is the difference between MXGC and MXGP MaxGuard cartridges?

A2: MXGC models use cellulose filter media, while MXGP models use polypropylene media. Media selection should be based on the process fluid, chemical compatibility and operating conditions.

Q3: Is MemKway MXGC100-40N-SM replacement filter designed for Parker MaxGuard systems?

A3: Yes. It is designed as a compatible replacement for selected Parker Fulflo MaxGuard applications. Final compatibility should be confirmed using the complete OEM part number, cartridge dimensions and seal configuration.

Q4: When should the MXGC100-40N-SM replacement cartridge be changed?

A4: Cartridge change-out should be based on system differential pressure, flow performance and process requirements. If your validated product specification uses 35 psid (2.4 bar) as the recommended change-out differential pressure, this value should remain consistent throughout the page.

Have questions about our filter cartridges, compatibility?